Böhler DCMS-IG
Hersteller
Ceweld product
Type
Copper coated welding wire for welding creep and hydrogen–resistant steels
classification
AWS
A 5.28: ER 80S-G
EN ISO
21952-A: W CrMo1Si
W.Nr.
1.7339
Anwendungen
High pressure boiler steels, offshore, repair, construction, pipelines, tubing etc.
Type
Copper coated welding wire for welding creep and hydrogen–resistant steels
Anwendungen
High pressure boiler steels, offshore, repair, construction, pipelines, tubing etc.
Eigenschaften
Extreme easy to weld with excellent welding properties. Suitable to offer creep resistance for working temperatures up to 550º Celsius.
Classification
AWS
A 5.28: ER 80S-G
EN ISO
21952-A: W CrMo1Si
F-nr
6
FM
3
W.Nr.
1.7339
Geeignet für
Typ 1Cr0,5Mo, ISO 15608: ~5,1
1.7335, 1.7262, 1.7728, 1.7218, 1.7225, 1.7258, 1.7354, 1.7357, 1.7205, 1.7218, 1.7225, 1.7228, 1.7254, 1.7262, 1.7335, 1.7337, 1.7350, 1.7354, 1.7357,
13CrMoV42, 13CrMo4-4, 13CrMo4-5, 15CrMo3, 15CrMo5, 13CrMoV42, 15Cr3, 16MnCr5, 20MnCr5, 15CrMo5, 24CrMo5, 25CrMo4, GS-22CrMo5, GS-22CrMo54, GS 17CrMo5-5, 16CrMoV4, 42CrMo4, 42CrMo4V, 41CrMo4V
ASTM A 182 Gr. F11 / F12; A 193 Gr. B7; A 213 Gr. T12; A 217 Gr. WC6; A 234 Gr. WP11; A335 Gr. P11, P12; A 336 Gr. F11, F12; A 426 Gr. CP12 ; A 199; A200; A 387 Gr A11 / 12
Zulassungen
CE
Schweißpositionen
Gas acc. EN ISO 14175
I1
Mechanische Gütewerte
Heat Treatment |
RP0,2 (MPa) |
Rm (MPa) |
A5 (%) |
Impact Energy (J) ISO-V | Hardness | |
---|---|---|---|---|---|---|
RT | -40°C | |||||
690°C±15°C 1h | 460 | 560 | 22 | 80 | 47 | HRc |